Gigabit Ethernet CWDM/DWDM

CWDM and DWDM SFP transceivers are widely used by companies which lease optical fibers, alternatively they also can be used to upgrade existing networks (by multiplying capacity of already installed optical cables without need for adding new ones). Thanks to optical multiplexing technology it is possible to send many separate data streams (channels) over same strain of fiber. Optical  (CWDM or DWDM) multiplexers and demultiplexers are needed at the ends of each fiber to extract/add particular channels and guide them to/from the appropriate connectors. Usage of such CWD/DWDM tranceivers can bring huge savings on the long-term basis. CWDM technology offers up to 18 channels, while DWDM brings up to 72 channels.

FTS-S12G-ZXXL-YYB

YY - denotes guaranteed power budget: (24 - 24dB, 28 - 28dB, 32 - 32dB, 36 - 36dB, 41 - 41dB)

Z - denotes type of WDM: (C - CWDM, D - DWDM)

XXin CWDM modules denotes wavelengths available to choose from [nm]: (27~61 - 1270~1610nm )

XXin DWDM modules denotes channel number of DWDM 100GHz grid

For details please check datasheets or contact support department.

Technical specification
Part number
Output Power RX Sensitivity RX Overload Wavelength Distance* Operating Temp DDMI
FTS-S12G-CxxL-24B 0~+5dBm -24dBm -3dBm 1271~1611nm 40km 0~70°C No
FTS-S12G-CxxL-24BI 0~+5dBm -24dBm -3dBm 1271~1611nm 40km -40~+85°C No
FTS-S12G-CxxL-24BD 0~+5dBm -24dBm -3dBm 1271~1611nm 40km 0~70°C Yes
FTS-S12G-CxxL-24BDI 0~+5dBm -24dBm -3dBm 1271~1611nm 40km -40~+85°C Yes
FTS-S12G-CxxL-28B 0~+5dBm -28dBm -9dBm 1271~1611nm 80km (1471~1611nm)
60km (1271~1451nm)
0~70°C No
FTS-S12G-CxxL-28BI 0~+5dBm -28dBm -9dBm 1271~1611nm 80km(1471~1611nm)
60km(1271~1451nm)
-40~+85°C No
FTS-S12G-CxxL-28BD 0~+5dBm -28dBm -9dBm 1271~1611nm 80km (1471~1611nm)
60km (1271~1451nm)
0~70°C Yes
FTS-S12G-CxxL-28BDI 0~+5dBm -28dBm -9dBm 1271~1611nm 80km (1471~1611nm)
60km (1271~1451nm)
-40~+85°C Yes
FTS-S12G-CxxL-32B 0~+5dBm -32dBm -9dBm 1271~1611nm 110km (1471~1611nm)
70km (1271~1451nm)
0~70°C No
FTS-S12G-CxxL-32BI 0~+5dBm -32dBm -9dBm 1271~1611nm 110km (1471~1611nm)
70km (1271~1451nm)
-40~+85°C No
FTS-S12G-CxxL-32BD 0~+5dBm -32dBm -9dBm 1271~1611nm 110km (1471~1611nm)
70km (1271~1451nm)
0~70°C Yes
FTS-S12G-CxxL-32BDI 0~+5dBm -32dBm -9dBm 1271~1611nm 110km (1471~1611nm)
70km (1271~1451nm)
-40~+85°C Yes
FTS-S12G-CxxL-36B 2~+6dBm -36dBm -9dBm 1471~1611nm 120km 0~70°C No
FTS-S12G-CxxL-36BI 2~+6dBm -36dBm -9dBm 1471~1611nm 120km -40~+85°C No
FTS-S12G-CxxL-36BD 2~+6dBm -36dBm -9dBm 1471~1611nm 120km 0~70°C Yes
FTS-S12G-CxxL-36BDI 2~+6dBm -36dBm -9dBm 1471~1611nm 120km -40~+85°C Yes
FTS-S12G-CxxL-41B 4~+7dBm -37dBm -10dBm 1471~1611nm 160km 0~70°C No
FTS-S12G-CxxL-41BI 4~+7dBm -37dBm -10dBm 1471~1611nm 160km -40~+85°C No
FTS-S12G-CxxL-41BD 4~+7dBm -37dBm -10dBm 1471~1611nm 160km 0~70°C Yes
FTS-S12G-CxxL-41BDI 4~+7dBm -37dBm -10dBm 1471~1611nm 160km -40~+85°C Yes
FTS-S12G-DxxL-24B -1~+5dBm -24dBm -9dBm DWDM 100 GHz grid 80km 0~70°C No
FTS-S12G-DxxL-24BI -1~+5dBm -24dBm -9dBm DWDM 100 GHz grid 80km -40~+85°C No
FTS-S12G-DxxL-24BD -1~+5dBm -24dBm -9dBm DWDM 100 GHz grid 80km 0~70°C Yes
FTS-S12G-DxxL-24BDI -1~+5dBm -24dBm -9dBm DWDM 100 GHz grid 80km -40~+85°C Yes
FTS-S12G-DxxL-32B 0~+5dBm -32dBm -9dBm DWDM 100 GHz grid 120km 0~70°C No
FTS-S12G-DxxL-32BI 0~+5dBm -32dBm -9dBm DWDM 100 GHz grid 120km -40~+85°C No
FTS-S12G-DxxL-32BD 0~+5dBm -32dBm -9dBm DWDM 100 GHz grid 120km 0~70°C Yes
FTS-S12G-DxxL-32BDI 0~+5dBm -32dBm -9dBm DWDM 100 GHz grid 120km -40~+85°C Yes

* - transmission distance depends on optical link attenuation